Entraco Bks

Office: 0253-6698128
Email : info@entracogroup.com, sales@entracogroup.com

Air Insulated Busducts

Get in Touch

    Air Insulated Busducts

    In Busducts we offers a full range of products to meet many diverse applications and products has been designed to meet specific installation requirements.
    Non-segregated phase busduct.
    One in which all phase conductoers are in a common metal enclosure without barriers between the phases.
    Segregated-phase busduct
    One in which all phase conductors are in a common metal enclosure but are segregated by barriers between phases.

    Product Offering

    Non Segregated Phase Busduct
    (Non Interleaved)
    (Rating 415V, 50hz Ranging from 200 Amps To 600 Amps)
    Non Segregated Phase Busduct
    (Low Reactance Interleaved)
    (Rating 415V, 50hz Ranging from 200 Amps To 8000 Amps)
    Non Segregated Phase Busduct
    (Rating 3.3, 6.6kV, 50hz
    Ranging from 630 Amps To 5000 Amps)
    Non Segregated Phase Busduct
    (Rating 3.3, 6.6, 12.47, 17.5, 22, 33kV, 50hz Ranging from 1250 Amps To 5000 Amps)

    Product Features

    Accessories

    Adaptors

    Termination adaptor box are designed to match the with the opening, drilling and bus extension detail supplied on the switchgear / transformer equipments. It includes a matching flange, fasteners, gaskets etc.

    Bellows

    Busduct Bellows are used to prevent transmission of vibration of electrical generators and provide the stress relief in ducting system due care of the thermal expansion and contraction of Busduc enclosure and civil tolerance during Bus Duct installation. Further it insulates the termination equipments connecting to busduct and thus do not let the busduct enclosure currents to flow in the connecting equipments. It is fabricated from slow in Stainless steeel/ EPDM/ Neoprene as per requirements

    Seal Off Bushings

    Epoxy Seal off bushing are provided at Power house wall and at Generator termination end to restrict the prorogation of fire in case of accident. For air pressurised location, Seal off bushing is also provided at Generator transformer end to form a close loop for compressed air

    Silicagel Breather

    Silica gel breathers are used to absorb the moisture content from the air inside Busduct enclosure so it protects from contamination at cooling / no load period

    Flexible Connectors

    Copper/Alluminum flexibles are provided at bus duct terminations i.e at Generator end, Generator transformer end, LAVT Cubicle, NG Cubicle and other connecting equipment end. Aluminum Flexibles are provided in the run of bus duct to take care of alignment, variation in bus bar lengths due to temperature variations

    Hot Dip Galvanized support Structure

    Hot-dip galvanizing is the process of immersing fabricated Steel support into a bath of molten zinc. The process is inherently simple which provides a distinct advangate over other corrosion protection methods resulting in superior corrosion resistance.